-
What's the difference between condenser and cooler?
2018-10-25
Today both Condenser and Cooler are very important heat exchanging components in commmercial or industrial refrigeration equipments, which are widely applied in many fields. Lots of customers who look for UAR for model selection are curious about the difference between Condenser and Cooler. So let’s make a brief introduction. 1)Phase change doesn’t occur in Cooler while it happens in Condenser. Ge...
view more
-
How to descale the water-cooled condenser
2024-04-11
How does the chiller descale the water-cooled condenser? Many refrigeration units adpot water-cooled cooling system. The inner wall of the water-cooled condenser is easy to scale. These scales will affect the heat exchange effect, resulting in an increase the condensing temperature, which will badly lower cooling capacity and increased unit power consumption. Water-cooled condensers should be regu...
view more
-
The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower
2019-05-08
H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower. The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the...
view more
-
How to manufacture the shell and tube heat exchanger I
2019-12-20
How to manufacture the shell and tube heat exchanger I Shell and tube heat exchanger is a kind of heat transfer device, which is composed of shell, tube plate, tube bundle, baffle and cover; How is the manufacture to produce the shell and tube heat exchanger? In the manufacturing of heat exchanger, the manufacturing process of cylinder, head and other parts is the same as that of general con...
view more
-
How to manufacture the shell and tube heat exchanger II
2019-12-20
How to manufacture the shell and tube heat exchanger II 4. Machining: after checking whether the dimension (outer diameter, thickness) and material of the tube sheet meet the requirements of the drawing, the surface roughness of the machined tube sheet shall not be greater than 25 μ m, and the tube sheet plane shall be visible. 5. Tube plate hole processing: after the tube plate hole of the ...
view more
-
How to produce a coil heat exchanger
2020-04-17
As we all know, coil heat exchangers are very important part of a air cooled chiller and air source heat pumps. How does a factory produce coil heat exchangers? Below are total 9 different procedures to maintain superior quality products. 1. Material preparation (copper tube, end plate, side plate, middle support plate, short U-head, gas / liquid tube, liquid distribution tube) 2. Fin stamping (pu...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Meet in Chongqing,Meet in Refrigeration Exhibition | Hstarschiller.com
2020-09-03
The 31st International Exhibition on Refrigeration, Air Conditioning, Heating, Ventilation and Food Frozen Exhibition (abbreviated as China Refrigeration Expo 2020) will be held at Chongqing International Expo Center from August 19 to 21, 2020. At that time, Guangzhou United A/C&R Co., Ltd. will bring its self-developed all-stainless steel products, titanium tube evaporator, and H.Stars ...
view more
-
Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
The Difference of Three Types Heat Exchanger in Hot Water unit
2020-10-26
In general, tube heat exchanger in hot water unit has long life span. Shell and tube heat exchanger structure: The shell and tube heat exchanger is composed of shell, heat transfer tube bundle, tube sheet, baffle plate (baffle plate), and tube box. The shell is mostly cylindrical with a tube bundle inside, and both ends of the tube bundle are fixed on the tube plate. There are two types of heat tr...
view more
-
What is a plate and shell heat exchanger | Hstarschiller.com
2020-12-07
The plate and shell heat exchanger is composed of a plate bundle composed of a plate group and a shell. It is a plasma arc welded corrugated plate group placed in the shell instead of the heat exchange tube of the original shell and tube heat exchanger. The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the plate side and the s...
view more
-
Upgraded high-efficiency plate and shell heat exchanger advantages
2021-04-02
The plate and shell heat exchanger is composed of a plate bundle and a shell composed of a plate group. The corrugated plate group is put into the shell by plasma arc welding, instead of the heat exchange tube of the original shell and tube heat exchanger, with corrugated The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the p...
view more
-
How to choose the material of seawater heat exchanger for offshore platform
2023-02-24
1、 Introduction: With the implementation of the national strategy of developing the ocean, the use of petrochemical devices on my country's offshore platforms has developed rapidly. Seawater heat exchanger is an important equipment that is most widely used in offshore platform operations. The heat exchange status of the heat exchanger directly affects the smooth operation of the entire platform an...
view more
-
Common Methods for Condenser Scale Removal
2024-03-15
Extended use of condensers in HVAC systems often leads to the formation of scale deposits in the pipes. If not addressed promptly, these deposits can compromise heat exchange efficiency, resulting in elevated condensation temperatures, reduced cooling capacity, and increased power consumption. Regular scale removal is crucial for maintaining optimal system performance. Methods for Scale Removal an...
view more
-
Exploring Electric Refrigeration Air Conditioning Systems
2024-03-29
Central air conditioning can be classified into three main types: electric refrigeration air conditioning, lithium bromide refrigeration air conditioning, and other energy source air conditioning. Among them, electric refrigeration air conditioning is the most commonly used form of air conditioning. Let's discuss the classification of electric refrigeration air conditioning in detail. I. Classific...
view more
-
A Guide to Select Heat Exchanger Material for Sea Water Marine Applications of Offshore Platforms
2024-04-30
The rapid development of petrochemical equipment on marine platforms all over the world, driven by the implementation of the national marine development strategy and the success of projects like the National Offshore Oil Corporation, underscores the importance of seawater heat exchangers. These devices are crucial for the smooth operation and economic performance of offshore platforms, impacting s...
view more
-
How to Solve Common Problems of Industrial Chiller Units
2024-05-09
Industrial chiller units play a crucial role in various industries, providing chilled water for processes such as plastics manufacturing, electronics production, and pharmaceuticals. However, like any mechanical system, chillers are prone to common problems that can affect their performance. In this blog post, we will discuss these issues and provide practical solutions to keep your industrial chi...
view more
-
Mastering HVAC Chiller Maintenance: Comprehensive Guide to Temperature Monitoring
2024-05-31
Maintaining optimal temperatures in HVAC chiller system components is essential for their efficient operation. Abnormal temperature ranges can signal potential issues that need timely analysis and intervention. While precise temperature measurements might be challenging, manual estimation by touch often helps in detecting these anomalies. Here’s an in-depth look at ten critical temperature points ...
view more