Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more
-
Detailed Guide on Water Quality and Temperature Settings for HVAC Chiller Systems
2024-05-23
Ensuring proper water quality and temperature settings is crucial in the operation and maintenance of HVAC chiller systems. This not only guarantees efficient system performance but also extends the equipment's lifespan and reduces operational costs. This article provides an in-depth look into the standards for water quality and temperature settings in chiller system maintenance. 1.Water Quality S...
view more
-
Mastering HVAC Chiller Maintenance: Comprehensive Guide to Temperature Monitoring
2024-05-31
Maintaining optimal temperatures in HVAC chiller system components is essential for their efficient operation. Abnormal temperature ranges can signal potential issues that need timely analysis and intervention. While precise temperature measurements might be challenging, manual estimation by touch often helps in detecting these anomalies. Here’s an in-depth look at ten critical temperature points ...
view more
-
How does an efficient cooling system ensure product quality and production efficiency in the injection molding industry
2024-08-08
In the injection molding industry, an efficient cooling system is crucial to ensuring product quality and production efficiency. To meet this need, H.Stars Group highly recommends using integrated chiller units. Key Advantages of Integrated Chiller Units 1. Multifunctional System Integrated chiller units are advanced systems that combine cooling, heating, and dehumidifying functions. They provide ...
view more
-
How do H.Stars air-cooled chillers stand out in industrial companies with extreme climates
2024-08-23
As industrial construction in Northwest China flourishes, the demand for efficient and eco-friendly refrigeration equipment has surged. The H.Stars air-cooled chiller, with its unique technological advantages and energy-saving features, has become a crucial force driving industrial development in this region. Advanced Air-Cooled Technology: H.Stars air-cooled chillers utilize advanced air-cooling ...
view more
-
Why Enterprises Favor Chiller Solutions with Water Tanks
2024-08-29
With the increasing demand for cooling technology in industrial and commercial sectors, chillers have become essential cooling equipment in the market. Among these, chiller solutions with water tanks are particularly favored by enterprises due to their unique advantages. Flexibility: Chillers with water tanks offer high flexibility. This solution allows for adjusting the water tank capacity based ...
view more
-
How to achieve a COP of 6.0 in Heat Recovery Chillers
2024-11-29
In the HVAC industry, heat recovery chillers are highly regarded for their energy-efficient properties. H.Stars has set a new benchmark by enhancing the coefficient of performance (COP) of its heat recovery chiller units to an impressive 6.0. This achievement reflects significant progress in energy utilization efficiency. Here’s how H.Stars achieved this feat. Key Innovations in Reaching a COP of ...
view more