Industrial Water Chillers are used in many Industries The cooling pump of industrial chilled water or other liquid is through process or laboratory equipment. Industrial water chillers are used to control the products, mechanisms and factory machinery industries. The industrial water chiller can be centralized; each unit cooling meets a variety of needs, or dispersed in each application or device,...
view more
-
What should I do if the air source heat pump unit is frosted in winter?
2018-12-11
What should I do if the air source heat pump unit is frosted in winter? How to quickly defrosting it ? Every heating season, there is always frosting problem, because once the frost can not be timely defrosted, the heating effect will be affected, and it might break down the system . However, there is no product that does not frost, and whether it is possible to defrost in time is the key. If the ...
view more
-
Indoor Artificial Ice Rink Refrigeration System Design And Selection
2021-03-11
Indoor Artificial Ice Rink Refrigeration System Design And Selection 1.Refrigeration System Features The refrigeration system of indoor ice skating rink usually adopts two refrigeration methods: direct expansion and indirect cooling. Direct expansion adopts "Hstars" brand condensing unit; indirect cooling adopts "Hstars" brand screw type low-temperature chiller, Glycol is used as a refrigerant to ...
view more
-
How to descale the water-cooled condenser
2024-04-11
How does the chiller descale the water-cooled condenser? Many refrigeration units adpot water-cooled cooling system. The inner wall of the water-cooled condenser is easy to scale. These scales will affect the heat exchange effect, resulting in an increase the condensing temperature, which will badly lower cooling capacity and increased unit power consumption. Water-cooled condensers should be regu...
view more
-
Dry Type and Flooded Type evaporator structure, principle, difference and advantages and disadvantages
2023-06-12
As we all know, the four major components of the refrigeration system are: compressor, evaporator, condenser, and throttling device. Among them, the type and characteristics of the compressor as the heart of the refrigeration system are more well known than the other three components. In addition, the evaporator is another key component. Do you know about the type and characteristics of the evapor...
view more
-
How to maintain the radiator
2019-04-19
How to maintain the radiator First, check the radiator interface for leaks During the heating period, the surface temperature of the radiator is high, so there will be a phenomenon of thermal expansion and contraction, especially at the pipe joint, which is the main point of water leakage. Once the heating is stopped, the interface is loose, which will cause water leakage. Therefore,...
view more
-
Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more
-
The Solution of Cold Water of Concrete Mixing Station
2022-12-16
1.Background of the project Temperature-controlled concrete is required for large-scale pouring of large hydro power dams, nuclear power, high-speed iron, and high-rise building foundations. During the concrete mixing process, the internal volume of the concrete hydration heat increases, especially the heat generated by the stirring under high temperature conditions is higher. In the subsequent cu...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
Magnetic Oil Free Centrifugal Chiller Advantages
2019-08-26
With the rapid development of the times and economy, energy conservation, environmental protection, and emission reduction have become an indispensable new era mission. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, greenhouse ef...
view more
-
How to manufacture the shell and tube heat exchanger I
2019-12-20
How to manufacture the shell and tube heat exchanger I Shell and tube heat exchanger is a kind of heat transfer device, which is composed of shell, tube plate, tube bundle, baffle and cover; How is the manufacture to produce the shell and tube heat exchanger? In the manufacturing of heat exchanger, the manufacturing process of cylinder, head and other parts is the same as that of general con...
view more
-
How to manufacture the shell and tube heat exchanger II
2019-12-20
How to manufacture the shell and tube heat exchanger II 4. Machining: after checking whether the dimension (outer diameter, thickness) and material of the tube sheet meet the requirements of the drawing, the surface roughness of the machined tube sheet shall not be greater than 25 μ m, and the tube sheet plane shall be visible. 5. Tube plate hole processing: after the tube plate hole of the ...
view more
-
How to produce a coil heat exchanger
2020-04-17
As we all know, coil heat exchangers are very important part of a air cooled chiller and air source heat pumps. How does a factory produce coil heat exchangers? Below are total 9 different procedures to maintain superior quality products. 1. Material preparation (copper tube, end plate, side plate, middle support plate, short U-head, gas / liquid tube, liquid distribution tube) 2. Fin stamping (pu...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Application of double source heat pump unit in automobile painting workshop
2020-07-16
Automobile production and manufacturing process includes stamping, welding, coating and general assembly. According to relevant statistics, coating workshop involves heating, cooling, power, communication control, lighting, etc. energy consumption accounts for a large proportion in the whole manufacturing process (stamping, welding, coating, etc.), accounting for more than 70% of the cost. The gen...