What's the difference between condenser and cooler?
2018-10-25
Today both Condenser and Cooler are very important heat exchanging components in commmercial or industrial refrigeration equipments, which are widely applied in many fields. Lots of customers who look for UAR for model selection are curious about the difference between Condenser and Cooler. So let’s make a brief introduction. 1)Phase change doesn’t occur in Cooler while it happens in Condenser. Ge...
view more
-
How to descale the water-cooled condenser
2024-04-11
How does the chiller descale the water-cooled condenser? Many refrigeration units adpot water-cooled cooling system. The inner wall of the water-cooled condenser is easy to scale. These scales will affect the heat exchange effect, resulting in an increase the condensing temperature, which will badly lower cooling capacity and increased unit power consumption. Water-cooled condensers should be regu...
view more
-
Dry Type and Flooded Type evaporator structure, principle, difference and advantages and disadvantages
2023-06-12
As we all know, the four major components of the refrigeration system are: compressor, evaporator, condenser, and throttling device. Among them, the type and characteristics of the compressor as the heart of the refrigeration system are more well known than the other three components. In addition, the evaporator is another key component. Do you know about the type and characteristics of the evapor...
view more
-
How to maintain the radiator
2019-04-19
How to maintain the radiator First, check the radiator interface for leaks During the heating period, the surface temperature of the radiator is high, so there will be a phenomenon of thermal expansion and contraction, especially at the pipe joint, which is the main point of water leakage. Once the heating is stopped, the interface is loose, which will cause water leakage. Therefore,...
view more
-
The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower
2019-05-08
H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower. The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the...
view more
-
Square Type Contra-flow closed Circuit Cooling Tower Working Principle
2019-05-14
Regarding to water cooled chiller working system, normally it needs to adopt water cooled chiller, cooling tower, water pump or tank etc. To familiar with H.Stars Group water cooled chiller system, here we are introducing you the working principle of square type contra-flow closed circuit cooling towers first. The working fluid (water, oil or other liquid) flows in the coil clock, ...
view more
-
The Solution of Cold Water of Concrete Mixing Station
2022-12-16
1.Background of the project Temperature-controlled concrete is required for large-scale pouring of large hydro power dams, nuclear power, high-speed iron, and high-rise building foundations. During the concrete mixing process, the internal volume of the concrete hydration heat increases, especially the heat generated by the stirring under high temperature conditions is higher. In the subsequent cu...
view more
-
The Reason That More and More People Choose Magnetic Oil Free Centrifugal Chiller
2019-07-30
With the rapid development of the times and economy, energy conservation and environmental protection and energy conservation and emission reduction have become an indispensable link. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, gre...
view more
-
Magnetic Oil Free Centrifugal Chiller Advantages
2019-08-26
With the rapid development of the times and economy, energy conservation, environmental protection, and emission reduction have become an indispensable new era mission. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, greenhouse ef...
view more
-
How can pharmaceutical air conditioning systems reduce operating costs by 40%
2019-08-30
Pharmaceutical factories need to meet GMP requirements in the production process, and the temperature, humidity and cleanliness should be controlled within a certain range. Under general circumstances, the temperature should be controlled at 18℃~26℃, the relative humidity should be controlled at 45%~65%, the pharmaceutical factory clean area is divided into ABCD level. The C and D level of the wor...
view more
-
The Solution of Food and Beverage Workshop Ice Water System
2019-09-04
Ⅰ.Demand Situation Food and beverage workshop ice water system engineering. The ice water system mainly meets the requirements of ice water on the production line. The required ice water temperature has two, one is 5 degrees ice water; the other is -5 degrees. Ⅱ. Load Calculation 1.5 degrees ice water total cooling capacity is 1500KW 2.-5 degrees ice water total cooling capacity 750KW 3.12 de...
view more
-
How to manufacture the shell and tube heat exchanger I
2019-12-20
How to manufacture the shell and tube heat exchanger I Shell and tube heat exchanger is a kind of heat transfer device, which is composed of shell, tube plate, tube bundle, baffle and cover; How is the manufacture to produce the shell and tube heat exchanger? In the manufacturing of heat exchanger, the manufacturing process of cylinder, head and other parts is the same as that of general con...
view more
-
How to manufacture the shell and tube heat exchanger II
2019-12-20
How to manufacture the shell and tube heat exchanger II 4. Machining: after checking whether the dimension (outer diameter, thickness) and material of the tube sheet meet the requirements of the drawing, the surface roughness of the machined tube sheet shall not be greater than 25 μ m, and the tube sheet plane shall be visible. 5. Tube plate hole processing: after the tube plate hole of the ...
view more
-
How to produce a coil heat exchanger
2020-04-17
As we all know, coil heat exchangers are very important part of a air cooled chiller and air source heat pumps. How does a factory produce coil heat exchangers? Below are total 9 different procedures to maintain superior quality products. 1. Material preparation (copper tube, end plate, side plate, middle support plate, short U-head, gas / liquid tube, liquid distribution tube) 2. Fin stamping (pu...
view more
-
Magnetic Bearing Centrifugal Chiller Units
2020-04-30
Magnetic Bearing Centrifugal Chiller installed for one of the commercial building This is a central air-conditioning project for the Industrial bank commercial building. The office has a total air-conditioning area of 8,000 square meters and other supporting areas of 2000 square meters. Device configuration instructions of Magnetic Bearing Centrifugal Chiller Units This project has selected two un...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Impact of New Coronavirus (COVID-19) on Refrigeration
2020-07-23
The current epidemic situation has changed both China and the world. Many companies are facing severe crises, and some large companies cannot bear it. They have begun to reduce personnel costs. News broke out one after another, Hisense Haier layoffs, and some companies laid off 500 people on the first day of resumption of work. In the next six months or longer, regardless of whether large, medium ...
view more
-
H.Stars ±0.1℃ high-precision chiller for Laboratory of the university
2020-09-03
Project Background The Synchrotron Radiation Laboratory of the University of Science and Technology of China has built China's first dedicated synchrotron radiation source mainly based on vacuum ultraviolet and soft X-rays. To ensure the reliability and stability of the light source, it is necessary to provide stable constant-temperature cooling water in the device. The temperature should be contr...
view more