Water-cooled screw type low-temperature chiller is designed for refrigeration, refrigeration and industrial cooling. It requires a complete range of models to meet the requirements of different cooling capacity and temperature requirements.
Item NO.:
40STD
Water Cooled Industrial Chiller Units
Introduction
Water-cooled screw type low-temperature chiller is designed for refrigeration, refrigeration and industrial cooling. It requires a complete range of models to meet the requirements of different cooling capacity and temperature requirements.
Cooling Consumption for reference
Sizing
Information for 1 ton cooling Consumption
Injection
Molding
30 lbs/hr
polyolefin's
50 lbs/hr
polystyrene
45 lbs/hr PVC
40 lbs/hr PET
Extrusion
50 lbs/hr
polyolefin's
75 lbs/hr
polystyrene
65 lbs/hr PVC
Blow
Molding
40 lbs/hr polyolefin's
Hydraulic
Cooling
0.1 ton of cooling per 1
HP
Industrial Chiller Unit for Plastic Industry
Cooling System Drawings - Industrial Cooling for Plastic Injection Machines
Features of Industrial Chiller for Plastic Industry
Higher Energy Efficient : COP of 12℃ outlet water temperature higher (15~20%) than normal unit of 7℃ outlet water temperature, means energy-saving efficient.
Oversized Condenser and Evaporator: Oversized condensers not only make for a long lasting compressor, they are also designed to operate in extreme conditions, i.e., above 45℃ and as low as -25℃, or at any temperature in between.
Heat Recovery: Supplying 55℃ free hot water, Heating Capacity approx. 1/3 of Cooling Capacity, increasing unit efficient about 5%.
Integrated System: Built in water tank and water pumps module set (with valves and strainer assemble in a module), no piping and wiring errors, simple installation, save time and labor cost.
Water Tank: For supplying a stable outlet water temperature, also supplying multiple outlet water temperature to different cooling requirements application.
Water Pumps: With pump controller making unit reliable and easy operation.
Non-rusting Water Piping: Pipes can be plastic or stainless steel with galvanized steel fittings.
Technical Parameters of Water Cooled Industrial Chiller Units
Notes
1. These are our standard chiller units, our factory accept produce non-standard unit according to your specification(inlet/out water temperature, power supply, refrigerant, etc.)
2. Rated Cooling Capacity Base: Chilled Water In/Outlet 17°C/12°C, Cooling Water In/Outlet: 30/35°C ,Air ambient: 35°C, fouling factor: 0.088m²·°C/KW;
3. Chilled Water Range: 5~ 20°C;
4. Cooling Water Range: 15 ~ 40°C;
5. Changes of Specification for improvement may be made without notice.