Industrial manufacturing glycol ultra low temperature recirculating air cooled chiller
Specification:
Model | Nominal cooling Capacity | Compressor Input Power KW | Capacity control % | Refrigerant charge kg | Condenser | Evaporator | Axial Fan | Operating sound level dB(A) | Shipping weight kg | Operating weight kg | |||||
kW | USRT | condenser | Chilled glycol flow m³/h | Water side max. pressure Mpa | Water pressure drop Kpa | Air flow x 1000 m³/h | Power kw x number | ||||||||
Inlet outlet pipe diameter in | |||||||||||||||
40STE-S140ADSL4 | 55.6 | 15.8 | 40.8 | 0,66,100 | 30 | Copper tube with corrugated aluminum fins | 2-1/2’’ | 10.1 | 1 | 28 | 40.2 | 2.0*2 | 68 | 1260 | 1370 |
40STE-S200ADSL4 | 78.4 | 22.3 | 56.9 | 0,50,75,100 | 42 | 3’’ | 14.3 | 1 | 55 | 57 | 1.2*4 | 68 | 1900 | 2080 | |
40STE-S260ADSL4 | 104.8 | 29.8 | 75.1 | 56 | 3’’ | 19.1 | 1 | 64 | 80 | 2.0*4 | 72 | 2700 | 2920 | ||
40STE-S300ADSL4 | 124 | 35.3 | 87.7 | 68 | 3’’ | 22.6 | 1 | 66 | 80 | 2.0*4 | 72 | 2780 | 3020 | ||
40STE-S340ADSL4 | 145.6 | 41.4 | 101.7 | 80 | 4’’ | 26.5 | 1 | 42 | 85 | 1.2*6 | 72 | 3220 | 3380 | ||
40STE-S370ADSL4 | 156.8 | 44.6 | 110.4 | 86 | 4’’ | 28.5 | 1 | 54 | 121 | 2.0*6 | 72 | 3240 | 3620 | ||
40STE-S410ADSL4 | 170.4 | 48.5 | 119.6 | 95 | 4’’ | 31 | 1 | 44 | 121 | 2.0*6 | 72 | 3500 | 3880 | ||
40STE-S460ADSL4 | 195.2 | 55.5 | 138.4 |
0,25,37.5,50,62. 5,75,87.5,100 |
115 | 4’’ | 35.5 | 1 | 55 | 114 | 1.2*8 | 75 | 4780 | 4950 | |
40STE-S520ADSL4 | 209.6 | 59.6 | 150.2 | 124 | 4’’ | 38.1 | 1 | 65 | 161 | 2.0*8 | 75 | 4850 | 5130 | ||
40STE-S600ADSL4 | 248 | 70.5 | 175.4 | 135 | 4’’ | 45.1 | 1 | 54 | 161 | 2.0*8 | 75 | 5360 | 5580 | ||
40STE-S680ADSL4 | 291.2 | 82.8 | 203.4 | 161 | 4’’ | 53 | 1 | 65 | 170 | 1.6*12 | 75 | 5660 | 6100 | ||
40STE-S740ADSL4 | 313.6 | 89.2 | 220.8 | 175 | 4’’ | 57.1 | 1 | 54 | 241 | 2.0*12 | 75 | 5720 | 6040 |
Customized Design
The industrial low temperature chiller can be designed according to the dimension of the machine room, and it can be delivered to the site by CKD (completely knock down ) or SKD(semi knock down) or the whole unit. Different power supply are available according to different countries and regions ,such as high-voltage non-standard chiller .
Waste heat generated in the refrigeration process is recovered by H.Stars patented heat recovery unit to provide free hot water up to 55°C. Boiler replacement to save operating cost.
According to user's requirements, H.Stars provides professional advice and selects the most suitable equipment which fits perfectly for each project. Different materials of heat exchange will be recommended to avoid corrosion and leakage according to user’s refrigeration medium used in the project.
Evaporative cooling technology with function of high heat exchange efficiency, low investment and save water.
Adopting Microcomputer controller, precise control, automatic loading and unloading with multiple functions such as time setting, fault record remote or central monitor. PLC is available for option.
The Glycol low temperature Chiller electrical protection system includes: reverse protection, phase loss protection, compressor and fan overcurrent protection, low temperature protection, high and low voltage protection, water flow protection, etc.
Ultra-low temperature chiller: chilled water outlet -35°C.
The heat recovery technology is to recover part or all of the same amount of heat energy from the chiller while it is cooling, to provide customers with a large amount of free hot water at 45~55 °C, suitable for electronics, chemical, pharmaceutical, food processing industries. Environmental protection and energy saving.
The heat recovery technology is an air-conditioning energy-saving patented invention. The principle is that when the unit is cooled, the heat originally discharged into the atmosphere can be recovered and converted into hot water, which can be used for living hot water, process heating. During heat recovery process, only the circulating water pump need to be installed, a large amount of free hot water is provided. At the same time, the cooling capacity of the unit is increased by about 5%, which is suitable for industrial production processes and commercial places with large demand.
In the transitional season and winter, the outdoor ambient temperature is lower than the process water temperature, taking advantage of the cold air outside to cool the process water without turning on the compressor. The dry cooler uses this principle to achieve the real non-compressor cooler. When the ambient temperature is lower than the process water temperature, the process water run through the interior of the dry cooler heat exchange tube. The fan is used to control the flow of outside cold air to cool the process water, and to ensure that the process water temperature meets the set requirements. It meets the requirements and saves 90% energy.
Central A/C cloud service system
Cloud service value:
Remote control adjustment
Remote monitoring
Remote upgrade
Fault warning
Remote diagnosis
Product distribution management
Historical data analysis
Product show:
Our Services:
1. After sale service: All of our machine provide long time after-sale service .
2. We accept OEM orders, processing according to buyer’s samples or drawing
3. On-time shipment
4. Product quality protection
5. Payment protection.
Application field:Industrial and commercial field
Packaging & Shipping: