H.Stars High Temperature Heat Pump 2023-09-05

Air-source High Temperature Heat Pump

Air-source High Temperature Heat Pump




· Adopt air as heat source
· Water temperature outlet 55℃ ~95℃ ·
· Ambient temperature: -30℃ ~55℃ ·90℃
· COP 2.3

·Suitable for high temperature heating industry
·Optional cold recovery system 5℃ ~30℃ frozen water



Water Source High Temperature Heat Pump

Water Source High Temperature Heat Pump

· Use water source to produce 55℃ ~90℃ hot water
· Not limited by the ambient temperature, the inlet temperature of the water source is 5℃ or above
· 3.0 Energy efficiency ratio when outlet water at 90℃
· Suitable for waste heat recovery and utilization、
· High temperature cycle use、High temperature heating、
· High temperature drying、High-temperature industrial


Variable working condition curve


Air source heating correction factor

Air source heating correction factor

Air source power correction factor

Air source power correction factor

Correction coef ficient for heating capacity of 80°C effluent water source

Correction coef ficient for heating capacity of 80°C effluent water source

Correction co efficient fo r heating capacity of 90°C outlet water source


Correction co efficient fo r heating capacity of 90°C outlet water source

Correction coef ficient of 90°C outlet water source power

Correction coef ficient of 90°C outlet water source power



Standard model parameter table

Technical parameters of air source high temperature heat pump
Refrigerant :R134a    Power Supply :3φ-380V-50Hz

Model

Nominal

heating

capacity

Input Power kW

Energy control  %

Refrigerant charge  kg

Condenser

Evaporator/ Fan

Operating sound

dB(A)

Shipping weight

kg

Operating weight

kg

kW

USRT

Condenser inlet

and outlet

pipe diameter in

Cooling wate

flow  m3/h

Water Side MAX

Pressure MPa

Condenser water

pressure drop kPa

quantity

Air Volume m3/h

PowerkW

80HW-M45/20AHS4

404

115

179

10

75

100

85

3

69

1

53

6

144000

12

75

2650

2900

80HW-M55/25AHS4

462

131

208

95

3

79

1

54

6

144000

12

76

2750

3050

80HW-M65/32AHS4

604

172

253

125

4

104

1

55

8

192000

16

77

2850

3200

80HW-M83/41AHS4

732

208

305

150

5

126

1

56

8

192000

16

78

3000

3250

80HW-M45/20AHD4

807

230

357

170

5

139

1

68

12

288000

24

79

3500

3750

80HW-M55/25AHD4

924

263

417

190

5

159

1

69

12

288000

24

80

3700

3950

80HW-M65/32AHD4

1207

343

505

250

8

208

1

74

16

384000

32

86

3860

4110

80HW-M83/41AHD4

1463

416

611

300

8

252

1

80

16

384000

32

90

3970

4220

Note:
1. Nominal working conditions: air dry/wet bulb temperature 20℃ /15℃ , hot water inlet/outlet temperature 85℃ /90℃ ; fouling coefficient 0.0088 ㎡ ·℃ /kW;
2. Ambient temperature range: 5℃ ~43℃ , please contact the manufacturer when the ambient temperature is lower than 5℃ ;
3. The highest outlet hot water temperature is 90℃ ;
4. Specifications and dimensions are subject to change due to product improvements without notice.

Technical parameters of air source high temperature heat pump
Refrigerant :R1234ze    Power Supply :3φ-380V-50Hz


Model

Nominal

heating

capacity

Input Power kW

Energy control  %

Refrigerant charge  kg

Condenser

Evaporator/ Fan

Operating sound

dB(A)

Shipping weight

kg

Operating weight

kg

kW

USRT

Condenser inlet

and outlet

pipe diameter in

Cooling wate

flow  m3/h

Water Side MAX

Pressure MPa

Condenser water

pressure drop kPa

quantity

Air Volume m3/h

PowerkW

80HW-U45/20AHS4

280

79

136

10

50

100

85

3

48

1

53

6

144000

12

75

2650

2900

80HW-U55/25AHS4

320

91

157

95

3

55

1

54

6

144000

12

76

2750

3050

80HW-U65/32AHS4

417

119

194

10

50

75

100

125

4

72

1

55

8

192000

16

77

2850

3200

80HW-U83/41AHS4

504

143

233

150

5

87

1

56

8

192000

16

78

3000

3250

80HW-U45/20AHD4

559

159

273

10

50

100

170

5

96

1

68

12

288000

24

79

3500

3750

80HW-U55/25AHD4

640

182

315

190

5

110

1

69

12

288000

24

80

3700

3950

80HW-U65/32AHD4

834

237

388

10

50

75

100

250

8

143

1

74

16

384000

32

86

3860

4110

80HW-U83/41AHD4

1008

287

466

300

8

173

1

80

16

384000

32

90

3970

4220



Note:
1. Nominal working conditions: air dry/wet bulb temperature 20℃ /15℃ , hot water inlet/outlet temperature 85℃ /90℃ ; fouling coefficient 0.0088 ㎡ ·℃ /kW;
2. Ambient temperature range: 5℃ ~43℃ , please contact the manufacturer when the ambient temperature is lower than 5℃ ;
3. The highest outlet hot water temperature is 90℃ ;
4. Specifications and dimensions are subject to change due to product improvements without notice.


Technical parameters of water source high temperature heat pump (80 ℃ )
Refrigerant:R134a  Power Supply:3φ-380V-50Hz


Model

Nominal heating capacity

Energy control  %

Refrigerant charge  kg

Condenser

Evaporator

Operating sound

dB(A)

Shipping weight

kg

Operating weight

kg

Heating capacity

kW

power  kW

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

80HW-M100WHS4

97

40

33

66

100

25

2-1/2

17

1

37

2

10

1

43

73

980

1230

80HW-M230WHS4

240

94

25

50

75

100

55

3

41

1

45

2-1/2

25

1

62

74

1350

1600

80HW-M260WHS4

247

96

45

3

42

1

46

3

26

1

63

75

1460

1710

80HW-M410WHS4

402

153

80

4

69

1

51

4

43

1

71

79

2030

2280

80HW-M470WHS4

457

172

120

5

79

1

53

4

49

1

72

80

2180

2430

80HW-M710WHS4

689

257

175

5

118

1

58

5

74

1

72

85

2980

3230

80HW-M790WHS4

760

281

195

5

131

1

64

6

82

1

73

86

3220

3470

Note:
1. Nominal heating capacity standard: heat source water inlet and outlet temperature 35°C/30°C, hot water inlet and outlet temperature 75°C/80°C; fouling coefficient 0.0088 ㎡ · °C/kW;
2. The minimum outlet temperature of heat source water is 15℃ ;
3. The maximum outlet temperature of hot water is 85℃ ;
4. Specifications and dimensions are subject to change due to product improvements without notice.

Technical parameters of water source high temperature heat pump (80 ℃ )
Refrigerant:R1234ze  Power Supply:3φ-380V-50Hz


Model

Nominal heating capacity

Energy control  %

Refrigerant charge  kg

Condenser

Evaporator

Operating sound

dB(A)

Shipping weight

kg

Operating weight

kg

Heating capacity

kW

power  kW

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

80HW-U100WHS4

106

34

33

66

100

35

2-1/2

18

1

37

2

12

1

43

73

980

123

80HW-U230WHS4

266

79

25

50

75

100

90

3

46

1

45

2-1/2

32

1

62

74

1350

1600

80HW-U260WHS4

273

81

95

3

47

1

46

3

33

1

63

75

1460

1710

80HW-U410WHS4

447

129

150

4

77

1

51

4

55

1

71

79

2030

2280

80HW-U470WHS4

508

145

170

5

87

1

53

4

62

1

72

80

2180

2430

80HW-U710WHS4

768

217

253

5

132

1

58

5

95

1

72

85

2980

3230

80HW-U790WHS4

847

236

280

5

146

1

64

6

105

1

73

86

3220

3470

Note:
1. Nominal heating capacity standard: heat source water inlet and outlet temperature 35°C/30°C, hot water inlet and outlet temperature 75°C/80°C; fouling coefficient 0.0088 ㎡ · °C/kW;
2. The minimum outlet temperature of heat source water is 15℃ ;
3. The maximum outlet temperature of hot water is 85℃ ;
4. Specifications and dimensions are subject to change due to product improvements without notice.

Technical parameters of water source high temperature heat pump (90 ℃ )
Refrigerant:R134a  Power Supply:3φ -380V-50Hz


Model

Nominal

heating

capacity

Energy control   %

Refrigerant charge

kg

Condenser

Evaporator

Operating sound

dB(A)

Shipping weight

kg

Operating weight

kg

Heating capacity

kW

power  kW

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

80HW-M45/20WHS4

360

170

10

75

100

150

5

62

1

56

4

33

1

70

73

2930

3180

80HW-M55/25WHS4

409

195

175

5

70

1

58

5

37

1

72

74

3000

3250

80HW-M65/32WHS4

534

243

205

5

92

1

73

5

50

1

88

75

3450

3700

80HW-M83/41WHS4

645

291

230

5

111

1

76

6

61

1

91

76

3700

3950

80HW-M45/20WHD4

720

340

300

5

124

1

81

6

65

1

92

81

3890

4140

80HW-M55/25WHD4

817

390

350

6

141

1

84

6

74

1

94

82

3960

4210

80HW-M65/32WHD4

1068

487

410

8

184

1

92

8

100

1

96

83

4100

4350

80HW-M83/41WHD4

1289

582

460

8

222

1

97

8

122

1

98

84

4370

4620

Note:
1. Nominal heating capacity standard: heat source water inlet and outlet temperature 12°C/7°C, hot water inlet and outlet temperature 85°C/90°C; fouling coefficient 0.0088 ㎡ · °C/kW;
2. The minimum outlet temperature of heat source water is 5℃ ;
3. The maximum outlet temperature of hot water is 90℃ ;
4. Specifications and dimensions are subject to change due to product improvements without notice.

Technical parameters of water source high temperature heat pump (90 ℃ )
Refrigerant:R1234ze  Power Supply:3φ -380V-50Hz


Model

Nominal

heating

capacity

Energy control   %

Refrigerant charge

kg

Condenser

Evaporator

Operating sound

dB(A)

Shipping weight

kg

Operating weight

kg

Heating capacity

kW

power  kW

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

Pipe connection in

Water flow m3/h

Water Side MAX

Pressure MPa

Water pressure

drop kPa

80HW-U45/20WHS4

275

134

10

50

100

80

5

47

1

56

4

24

1

70

73

2930

3180

80HW-U55/25WHS4

315

154

100

5

54

1

58

5

28

1

72

74

3000

3250

80HW-U65/32WHS4

410

191

10

50

75

100

120

5

70

1

73

5

38

1

88

75

3450

3700

80HW-U83/41WHS4

495

229

150

5

85

1

76

6

46

1

91

76

3700

3950

80HW-U45/20WHD4

549

267

10

50

100

160

5

94

1

81

6

48

1

92

81

3890

4140

80HW-U55/25WHD4

629

308

200

6

108

1

84

6

55

1

94

82

3960

4210

80HW-U65/32WHD4

819

381

10

50

75

100

240

8

141

1

92

8

75

1

96

83

4100

4350

80HW-U83/41WHD4

990

458

300

8

170

1

97

8

92

1

98

84

4370

4620

Note:
1. Nominal heating capacity standard: heat source water inlet and outlet temperature 12°C/7°C, hot water inlet and outlet temperature 85°C/90°C; fouling coefficient 0.0088 ㎡ · °C/kW;
2. The minimum outlet temperature of heat source water is 5℃ ;
3. The maximum outlet temperature of hot water is 90℃ ;
4. Specifications and dimensions are subject to change due to product improvements without notice.

Standard Model Parameter Table Dimensions

Air source high temperature heat pump




Model

A

B

C

D

E

80HW-M/U45/20AHS4

3400

2100

2400

1400

2050

80HW-M/U55/25AHS4

3400

2100

2400

1400

2050

80HW-M/U65/32AHS4

4500

2100

2400

2025

2050

80HW-M/U83/41AHS4

4500

2100

2400

2025

2050




Model

A

B

C

D

E

80HW-M/U45/20AHD4

6800

2100

2400

1550

2050

80HW-M/U55/25AHD4

6800

2100

2400

1550

2050

80HW-M/U65/32AHD4

9000

2100

2400

2025

2050

80HW-M/U83/41AHD4

9000

2100

2400

2025

2050

Model

A

B

C

D

E

80HW-M/U100WHS4

2150

800

1500

900

600

80HW-M/U230WHS4

2650

1400

1500

1400

1050

80HW-M/U260WHS4

2900

1400

1500

1400

1050

80HW-M/U410WHS4

2960

1400

1550

1400

1050

80HW-M/U470WHS4

2960

1400

1550

1400

1050

80HW-M/U710WHS4

3700

1600

1800

1600

1250

80HW-M/U790WHS4

3700

1800

2000

1600

1250

80HW-M/U45/20WHS4

3000

1400

1800

1400

1050

80HW-M/U55/25WHS4

3700

1600

1800

1600

1250

80HW-M/U65/32WHS4

3700

1800

2000

1600

1250

80HW-M/U83/41WHS4

3700

1800

2000

1600

1250

Water source high temperature heat pump

Model

A

B

C

D

E

80HW-M/U100WHS4

2150

800

1500

900

600

80HW-M/U230WHS4

2650

1400

1500

1400

1050

80HW-M/U260WHS4

2900

1400

1500

1400

1050

80HW-M/U410WHS4

2960

1400

1550

1400

1050

80HW-M/U470WHS4

2960

1400

1550

1400

1050

80HW-M/U710WHS4

3700

1600

1800

1600

1250

80HW-M/U790WHS4

3700

1800

2000

1600

1250

80HW-M/U45/20WHS4

3000

1400

1800

1400

1050

80HW-M/U55/25WHS4

3700

1600

1800

1600

1250

80HW-M/U65/32WHS4

3700

1800

2000

1600

1250

80HW-M/U83/41WHS4

3700

1800

2000

1600

1250



Model

A

B

C

D

E

80HW-M/U45/20WHD4

4000

1650

1900

1800

1250

80HW-M/U55/25WHD4

4600

1700

1900

2000

1250

80HW-M/U65/32WHD4

4600

1850

2000

2000

1450

80HW-M/U83/41WHD4

4700

1850

2000

2000

1650

Copyright © 2015-2024 H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.

/ Blog / Sitemap / XML
  • 1
  • Linkedin
  • twitter
  • instagram
  • youtube
welcome to H.Stars