High temperature air source heat pump:
▽Using air as heat source
▽Outlet water temperature 55℃—95℃
▽Ambient temperature -30℃—55℃
▽90℃ water outlet temperature, energy efficiency ratio 2.3
▽Suitable for high temperature heating
95 ℃ high temperature water source air Source Heat Pump manufacturer
High temperature heat pump is Safe, Efficient and Energy saving.
▽Using air as heat source
▽Outlet water temperature 55℃—95℃
▽Ambient temperature -30℃—55℃
▽90℃ water outlet temperature, energy efficiency ratio 2.3
▽Suitable for high temperature heating
Water source heat pump unit
▽Use water source or recycled hot water source system
Take 55℃—120℃ hot water
▽It is not restricted by the ambient temperature, and the inlet water temperature is required to be 5℃ or above
▽Energy efficiency ratio 3.0 when 110℃ effluent
▽Suitable for waste heat recovery and utilization
▽High temperature cycle use
▽High temperature heating
▽High temperature drying
▽High temperature industrial manufacturing process
Air source high temperature heat pump unit
Technical parameters of high temperature air source heat pump
Refrigerant:R134a Power Supply:3φ-380V-50Hz
Model
Nominal
Heating
Capacity
Input
Power
kW
Capacity
Control
%
Refrigerant
Charge kg
Condenser
Evaporator/fan
Noise dB(A)
Unit
Weight kg
Running
weight kg
Condenser inlet
and outlet pipe diameter
inch
Cooling water
flow m3/h
Maximum pressure
on the water side MPa
Condenser water
pressure drop kPa
QTY
Air
Flow m3/h
Power
kW
kW
USRT
80HW-M45/20AHS4
404
115
179
10,50,100
85
3″
69
1
53
6
144000
12
75
2650
2900
80HW-M55/25AHS4
462
131
208
95
3″
79
1
54
6
144000
12
76
2750
3050
80HW-M65/32AHS4
604
172
253
10,50,75,100
125
4″
104
1
55
8
192000
16
77
2850
3200
80HW-M83/41AHS4
732
208
305
150
5″
126
1
56
8
192000
16
78
3000
3250
80HW-M45/20AHD4
807
230
357
10,50,100
170
5″
139
1
68
12
288000
24
79
3500
3750
80HW-M55/25AHD4
924
263
417
190
5″
159
1
69
12
288000
24
80
3700
3950
80HW-M65/32AHD4
1207
343
505
10,50,75,100
250
8″
208
1
74
16
384000
32
86
3860
4110
80HW-M83/41AHD4
1463
416
611
300
8″
252
1
80
16
384000
32
90
3970
4220
Note: 1. Nominal working conditions: air dry/wet bulb temperature 20℃/15℃, hot water inlet/outlet temperature 85℃/90℃; fouling coefficient 0.088㎡•℃/kW;
2. Ambient temperature range: 5℃~43℃, please contact the manufacturer when the ambient temperature is lower than 5℃;
3. The highest hot water temperature is 95℃;
4. Specifications and dimensions are subject to change due to product improvements without notice.
High temperature water source heat pump
Technical parameters of High temperature water source heat pump(80 ℃)
Refrigerant:R134a Power Supply:3φ-380V-50Hz
Model
Nominal
Heating
Capacity
Capacity
Control
%
Refrigerant
Charge kg
Condenser
Evaporator
Noise dB
(A)
Unit
Weight kg
Running
weight kg
kW
US
RT
Condenser inlet
and outlet pipe diameter
inch
Cooling water
flow m3/h
Maximum pressure
on the water side MPa
Condenser water
pressure drop kPa
inlet and outlet
pipe diameter
inch
water flow m3/h
Maximum pressure
on the water side MPa
water pressure
drop kPa
80HW-M100WHS4
97
40
33 66
100
25
2-1/2″
17
1
37
2″
10
1
43
73
980
1230
80HW-M230WHS4
240
94
35 50
75 100
55
3″
41
1
45
2-1/2″
25
1
62
74
1350
1600
80HW-M260WHS4
247
96
25 50
75 100
45
3″
42
1
46
3″
26
1
63
75
1460
1710
80HW-M410WHS4
402
153
80
4″
69
1
51
4″
43
1
71
79
2030
2280
80HW-M470WHS4
457
172
120
5″
79
1
53
4″
49
1
72
80
2180
2430
80HW-M710WHS4
689
257
175
5″
118
1
58
5″
74
1
72
85
2980
3230
80HW-M790WHS4
760
281
30 50
75 100
195
5″
131
1
64
6″
82
1
73
86
3220
3470
Note: 1. Nominal heating capacity benchmark: heat source water inlet and outlet temperature 35°C/30°C, hot water inlet and outlet temperature 75°C/80°C; fouling coefficient 0.088㎡·°C/kW;
2. The minimum outlet temperature of heat source water is 15℃;
3. The maximum outlet temperature of hot water is 85℃;
4. Specifications and dimensions are subject to change due to product improvements without notice.
Refrigerant:R134a Power Supply:3φ-380V-50Hz
Model
Nominal
Heating
Capacity
Capacity
Control
%
Refrigerant
Charge kg
Condenser
Evaporator
Noise dB
(A)
Unit
Weight kg
Running weight kg
kW
US
RT
Condenser inlet
and outlet pipe diameter
inch
Cooling water
flow m3/h
Maximum pressure
on the water side MPa
Condenser water
pressure drop kPa
inlet and outlet
pipe diameter
inch
water flow m3/h
Maximum pressure
on the water side MPa
water pressure
drop kPa
80HW-M45/20WHS4
360
170
10,50,100
150
5″
62
1
56
4″
33
1
70
73
2930
3180
80HW-M55/25WHS4
409
195
175
5″
70
1
58
5″
37
1
72
74
3000
3250
80HW-M65/32WHS4
534
243
10,50,75,100
205
5″
92
1
73
5″
50
1
88
75
3450
3700
80HW-M83/41WHS4
645
291
230
5″
111
1
76
6″
61
1
91
76
3700
3950
80HW-M45/20WHD4
720
340
10,50,100
300
5″
124
1
81
6″
65
1
92
81
3890
4140
80HW-M55/25WHD4
817
390
350
6″
141
1
84
6″
74
1
94
82
3960
4210
80HW-M65/32WHD4
1068
487
10,50,75,100
410
8″
184
1
92
8″
100
1
96
83
4100
4350
80HW-M83/41WHD4
1289
582
460
8″
222
1
97
8″
122
1
98
84
4370
4620
2. The minimum outlet temperature of heat source water is 5℃;
3. The maximum outlet temperature of hot water is 95℃;
4. Specifications and dimensions are subject to change due to product improvements without notice.