Combined cooling and heating system tri-function chiller

H.Stars air source cooling and heating chillers,also called Tri-function chillers have five major functions: cooling, heating, hot water, cooling with hot water, and heating with hot water.
It can be used in summer for cooling, and at the same time to produce hot water, or just for cooling alone; in spring and autumn when there is no need for cooling and heating, it can be used to produce hot water; and it can be used for heating and producing hot water in winter.
The integrated microcomputer control system enables them to automatically identify and adjust operating conditions according to actual water temperature and purpose of use. In addition to fully automated intelligent control, they may also be subject to remote management program, in which remote service is made possible through feedback of system operation information.
These energy-saving, environmentally friendly, multi-functional, compact structured, space saving, and easy-to-install systems are suitable for hotels, villas, hospitals, schools and other places with demand for cooling and heating.

Inquiry now
Product Detail

Combined cooling and heating system tri-function chiller


Cooling/hot water mode

When turned on, the combined cooling and heating system chiller is in the cooling/hot water mode, which produces free domestic hot water during the cooling process; when the air conditioning chilled water reaches its set value but the domestic hot water does not,the system will automatically switch to hot water mode;

when the domestic hot water reaches its set value, but the air conditioning chilled water does not, the system will automatically switch to cooling water mode; and when both air conditioning chilled water and domestic hot water reach their own set value, the compressor stops and the system enters into the standby mode .


Heating/hot water mode

Winter heating-hot water mode 1 (with priority on hot water): When turned on, the system will go into hot water mode, and when the hot water temperature reaches its set value, the system will automatically switch to heating mode; when the hot water temperature drops below the set value again, the system

will switch back into hot water mode again; and when both hot water and floor heating temperatures reach their respective set values, the compressor stops and the system enters into the standby mode. Winter heating-hot water mode 2 (with priority on heating): When turned on, the system will go into heating mode, and when the heating reaches its set value, the system will automatically switch to hot water mode; when the heating temperature drops below the set value again, the system will switch back into heating mode; and when both hot water and floor heating temperatures reach their respective set values, the compressor stops and the system enters into the standby mode.


Hot water mode

The system will run the mode of producing domestic hot water; when the hot water temperature reaches the set value, the compressor stops and the system enters into the standby mode; and when the hot water drops below the set value again, the system will automatically start to produce hot water.


Heating mode

The system will run the heating mode; when the floor heating temperature reaches the set value, the compressor stops and the system enters into the standby mode; and when the heating temperature drops below the set value again, the system will automatically start the heating process.



Cooling mode

The system will run the cooling mode; when the cooling temperature reaches the set value, the compressor stops and the system enters into the standby mode; and when the chilled water temperature rises above the set value again, the system will automatically start the cooling process. (To avoid frequent switches between modes, cooling mode can be selected in summer, when hot water is not needed)

Specification:

Technical Parameter Table of H.Stars Scroll Tri-function Systems

Refrigerant: R134a Power supply: 380V-3Ph-50Hz


Model

Nominal cooling

Nominal hot water

Floor heating

Chilled water

Hot water

Heat exchanger

Axial fan

Running noise B(A)

Shipping weight kg

Running weight kg

Cooling capacity KW

Compressor input power KW

Heating capacity KW

Compressor input power KW

Heating capacity KW

Compressor input popup KW

Diameter of inlet and outlet pipes in

Water flow rate m³/h

Water pressure drop kPa

Diameter of inlet and outlet pipes in

Water flow rate m³/h

Water pressure drop kPa

water side

Air side

Air flow rate *1000 m³/h

Input power KW* Qty

30ST-M10AS4

17

5

26

7

18

5

1-1/2’

4

23

1-1/2’

4

23

Shell and tube type

Hydrophilic corrugated aluminum with copper pipe sleeve

14.5

1.2*1

65

620

730

30ST-M12.5AS4

21

7

32

8

22

7

2’

5

28

2’

6

28

14.5

1.2*1

66

680

790

30ST-M15AS4

26

8

39

10

27

8

2’

6

30

2’

7

30

20

2.0*1

67

830

940

30ST-M20AD4

34

10

52

14

36

10

2’

7

28

2’

9

28

29

1.2*2

67

980

1090

30ST-M25AD4

42

14

64

16

44

14

2’

9

28

2’

11

28

29

1.2*2

68

1030

1140

30ST-M30AD4

52

16

78

20

54

16

2-1/2’

11

32

2-1/2’

13

32

40

2.0*2

69

1280

1390


Notes:
1. Nominal cooling capacity: ambient dry/wet bulb temperature 35℃ /24℃ , and temperature of inlet/outlet air-conditioning chilled water 12℃ /7℃ ;
2. Floor heating capacity: ambient dry/wet bulb temperature 7℃ /6℃ , and temperature of inlet/outlet air-conditioning hot water 40℃ /45℃ ;
3. Nominal hot water capacity: ambient dry/wet bulb temperature 20℃ /15℃ , and temperature of inlet/outlet domestic hot water 50℃ /55℃ ;
4. Cooling ambient temperature range: 15 ~ 43℃ ; heating ambient temperature range: -10 ~ 43℃ , and fouling coefficient 0.088m ² •℃ /kW;
5. Optional voltages: 220V, 380V, 400V, 415V, 440V, 460V
6. Specifications and dimensions are subject to change due to product improvement without prior notice
Technical Parameter Table of H.Stars Screw Tri-function Systems
Refrigerant: R134a Power supply: 380V-3Ph-50Hz


Model

Nominal cooling

Nominal hot water

Floor heating

Chilled water

Hot water

Heat exchanger

Axial fan

Running noise B(A)

Shipping weight kg

Running weight kg

Cooling capacity KW

Compressor input power KW

Heating capacity KW

Compressor input power KW

Heating capacity KW

Compressor input popup KW

Diameter of inlet and outlet pipes in

Water flow rate m³/h

Water pressure drop kPa

Diameter of inlet and outlet pipes in

Water flow rate m³/h

Water pressure drop kPa

water side

Air side

Air flow rate *1000 m³/h

Input power KW* Qty

60ST-M190AS4

75

23

110

29

78

22

2-1/2’

16

26

1-1/2’

19

26

Shell and tube type

Hydrophilic corrugated aluminum with copper pipe sleeve

57

1.2*4

74

1730

1880

60ST-M270AS4

107

32

156

41

111

31

3’

23

32

2’

27

32

80

2.0*4

78

2200

2450

60ST-M360AS4

143

43

208

54

147

41

3’

31

35

2’

36

35

114

1.2*8

79

3190

3470

60ST-M420AS4

169

49

244

62

173

47

3’

36

50

2’

42

50

115

1.2*8

80

3560

3940

60ST-M480AS4

195

56

282

71

199

54

4’

42

55

4’

49

55

115

1.2*8

80

3750

4170

60ST-M520AS4

217

60

311

77

220

59

4’

47

58

4’

53

58

161

2.0*8

82

3920

4250

60ST-M580AS4

236

68

341

86

241

66

4’

51

64

4’

59

64

161

2.0*8

83

4040

4430


Notes:
1. Nominal cooling capacity: ambient dry/wet bulb temperature 35℃ /24℃ , and temperature of inlet/outlet air-conditioning chilled water 12℃ /7℃ ;
2. Floor heating capacity: ambient dry/wet bulb temperature 7℃ /6℃ , and temperature of inlet/outlet air-conditioning hot water 40℃ /45℃ ;
3. Nominal hot water capacity: ambient dry/wet bulb temperature 20℃ /15℃ , and temperature of inlet/outlet domestic hot water 50℃ /55℃ ;
4. Cooling ambient temperature range: 15 ~ 43℃ ; heating ambient temperature range: -10 ~ 43℃ , and fouling coefficient 0.088m 2 •℃ /kW;
5. Optional voltages: 220V, 380V, 400V, 415V, 440V, 460V
6. Specifications and dimensions are subject to change due to product improvement without prior notice

Product photos:


tri-function chiller

combined cooling and heating system chiller

cooling and heating system


Contact Us For More Details
contact experts
Contact Person: Ms May Chow Mobile/WhatsApp: +86 18665672648 Tel: +86-20-62266755 Ext. 886 Fax: +86-20-82266081 Email: maychow@hstars.com.cn
Related Products
water cooled scroll chillers water cooled scroll chillers
water cooled scroll chillers Hstars closed box design air conditioner is a kind of split type air conditioner, which is widely used in homes and small offices. Cabinet air conditioners have the advantages of high power and strong wind power. The unit has 8 standard specifications and cooling water inlet temperature. Range 21-35 ° C. Brand: Hstars Cooling capacity range: 25.7kw ~ 147.7kw Applications: Factory, restaurant, shopping mall, office and other air conditioning systems.
Industrial Integrated Chiller Industrial and Commercial Integrated Chiller Machine
Industrial  and commercial All in one integrated product is designed for different industries with the advantages of high integration, simple and convenient installation, and reduced engineering installation costs.
low temperature air source multifunction chiller Ultra-Low Temperature Air Source Multifunction Chiller
The air source cold and heat energy unit is a multi-functional air conditioning unit, which has three working conditions of refrigeration, heating and domestic hot water production. It can be automatically switched according to the ambient temperature and hot water demand, which is energy efficient.
Air-Cooled Multi Function Chiller 8 - 192 TR Air Source Multi Function Chiller Scroll/Screw Type Chiller for Hotel/Hospital/Villa Use
The air source multifunction chiller is a multi-functional air conditioning unit, which has three working conditions of refrigeration, heating and domestic hot water production. It can be automatically switched according to the ambient temperature and hot water demand, which is widely applied for hotels, hospitals, commercial and residential communities, villas, etc
Hotel Chiller HVAC System Screw Type Chiller For Hotel Central Air-conditioning System
Water cooled screw type chiller is specially design for chiller site installation, which need building machine room and project period is tight. It combined H'Stars experience of refrigerating and site installation to develop, design and manufacturing series of package chiller. According to different project installation requirement, we can design different specification and dimension package chiller. Chiller cooling capacity and chiller water range is wide.
Modular Type Central Air Conditioning Low Noise Rooftop Air Cooled Chiller Unit A/C for Hotel/Hospital Use Modular Type Central Air Conditioning Low Noise Rooftop Air Cooled Chiller Unit A/C for Hotel/Hospital Use
H.stars modular type air-cooled chiller unit adopts the advanced 5:6 high-efficiency screw compressor as the cooling "heart" with self-made condenser and evaporator of high quality, equipped with well-known brand electric control components. It is suitable for all kinds of places for cooling and heating supply.

Copyright © 2015-2024 H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.

/ Blog / Sitemap / XML
  • 1
  • Linkedin
  • twitter
  • instagram
  • youtube
welcome to H.Stars

Home

Products

about

contact