-
What's the difference between condenser and cooler?
2018-10-25
Today both Condenser and Cooler are very important heat exchanging components in commmercial or industrial refrigeration equipments, which are widely applied in many fields. Lots of customers who look for UAR for model selection are curious about the difference between Condenser and Cooler. So let’s make a brief introduction. 1)Phase change doesn’t occur in Cooler while it happens in Condenser. Ge...
view more
-
What is the application for industrial chillers
2020-09-15
Industrial Water Chillers are used in many Industries The cooling pump of industrial chilled water or other liquid is through process or laboratory equipment. Industrial water chillers are used to control the products, mechanisms and factory machinery industries. The industrial water chiller can be centralized; each unit cooling meets a variety of needs, or dispersed in each application or device,...
view more
-
Indoor Artificial Ice Rink Refrigeration System Design And Selection
2021-03-11
Indoor Artificial Ice Rink Refrigeration System Design And Selection 1.Refrigeration System Features The refrigeration system of indoor ice skating rink usually adopts two refrigeration methods: direct expansion and indirect cooling. Direct expansion adopts "Hstars" brand condensing unit; indirect cooling adopts "Hstars" brand screw type low-temperature chiller, Glycol is used as a refrigerant to ...
view more
-
Choosing a network monitoring industrial water cooled Chiller from HStars
2019-02-21
Choosing a network monitoring industrial water cooled Chiller from HStars The single-chip controller of the HStars scroll typr chiller can customize the network monitoring function. The specific functions are as follows: 1.Industrial water cooled chiller networked monitoring the operational items-- Start command, stop command, reset command, cancel preheat, open external circulation pump, s...
view more
-
The difference between square type crossflow closed circuit cooling tower and traditional open cooling tower
2019-05-08
H.Stars Group water cooled chiller unit always need to adopt cooling tower to supply water to the cooling system . Hence, H.Stars has summarizes the difference between square type cross flow closed circuit cooling tower and traditional open cooling tower. The cooling water of the open cooling tower is directly contact with the air for heat exchange in the packing process, so the purity of the...
view more
-
Square Type Contra-flow closed Circuit Cooling Tower Working Principle
2019-05-14
Regarding to water cooled chiller working system, normally it needs to adopt water cooled chiller, cooling tower, water pump or tank etc. To familiar with H.Stars Group water cooled chiller system, here we are introducing you the working principle of square type contra-flow closed circuit cooling towers first. The working fluid (water, oil or other liquid) flows in the coil clock, ...
view more
-
Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The Solution of Cold Water of Concrete Mixing Station
2022-12-16
1.Background of the project Temperature-controlled concrete is required for large-scale pouring of large hydro power dams, nuclear power, high-speed iron, and high-rise building foundations. During the concrete mixing process, the internal volume of the concrete hydration heat increases, especially the heat generated by the stirring under high temperature conditions is higher. In the subsequent cu...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
The Reason That More and More People Choose Magnetic Oil Free Centrifugal Chiller
2019-07-30
With the rapid development of the times and economy, energy conservation and environmental protection and energy conservation and emission reduction have become an indispensable link. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, gre...
view more
-
The Solution of Food and Beverage Workshop Ice Water System
2019-09-04
Ⅰ.Demand Situation Food and beverage workshop ice water system engineering. The ice water system mainly meets the requirements of ice water on the production line. The required ice water temperature has two, one is 5 degrees ice water; the other is -5 degrees. Ⅱ. Load Calculation 1.5 degrees ice water total cooling capacity is 1500KW 2.-5 degrees ice water total cooling capacity 750KW 3.12 de...
view more
-
What should you pay attention in the Design and Construction of 5000RT cold room
2019-09-12
The 5000RT cold room generally equipped with various refrigeration equipment, which can be controlled and maintained stable low temperature facilities. Its basic components are: refrigeration system, warehouse with certain thermal insulation performance, attribute buildings, etc. H.Stars Group has been committed to providing customers with complete low temperature condensing c...
view more
-
How to find the right Explosion-proof chillers for industrial process cooling
2019-11-15
Introduction of explosion-proof chiller: International Industries have demanded a lot from their HVAC machines. Some of equipment might be susceptible to explosions inside and outside their circuitry. Getting an explosion-proof chiller is essential for many industrial environments. However ,very few factory can manufacture explosion-proof chillers with mature technology and ski...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Application of double source heat pump unit in automobile painting workshop
2020-07-16
Automobile production and manufacturing process includes stamping, welding, coating and general assembly. According to relevant statistics, coating workshop involves heating, cooling, power, communication control, lighting, etc. energy consumption accounts for a large proportion in the whole manufacturing process (stamping, welding, coating, etc.), accounting for more than 70% of the cost. The gen...
view more
-
H.Stars ±0.1℃ high-precision chiller for Laboratory of the university
2020-09-03
Project Background The Synchrotron Radiation Laboratory of the University of Science and Technology of China has built China's first dedicated synchrotron radiation source mainly based on vacuum ultraviolet and soft X-rays. To ensure the reliability and stability of the light source, it is necessary to provide stable constant-temperature cooling water in the device. The temperature should be contr...
view more
-
H.Stars Group industrial water screw chillers are ranked top 75 of the world tire industry
2020-09-03
Anhui Jiatong Tire Co., Ltd. is a large-scale tire manufacturing enterprise solely established by Jiatong Group Singapore Jiatong Tire Co., Ltd. Among the 55 major tire manufacturers in China, Anhui Jiatong ranks first in tire production and sales; in the world tire industry The Top 75 ranked 21st in total sales in 2001. The chilled water supply system mainly provides 7-12℃ chilled...
view more
-
How Does H.Stars Group Produce A High Quality Water Cooled Chiller
2020-09-18
Since H.Stars Group has been established for more than 28 years so far, some of you might wonder how H.Stars produces a high quality water cooled chiller. Below is the detailed production process with strict quality control system and 100% testing before delivery. 1. Chiller Frame welding: clean the bracket and select the appropriate welding method according to the specifications of the welding ma...
view more