What should I do if the air source heat pump unit is frosted in winter?
2018-12-11
What should I do if the air source heat pump unit is frosted in winter? How to quickly defrosting it ? Every heating season, there is always frosting problem, because once the frost can not be timely defrosted, the heating effect will be affected, and it might break down the system . However, there is no product that does not frost, and whether it is possible to defrost in time is the key. If the ...
view more
-
Dry Type and Flooded Type evaporator structure, principle, difference and advantages and disadvantages
2023-06-12
As we all know, the four major components of the refrigeration system are: compressor, evaporator, condenser, and throttling device. Among them, the type and characteristics of the compressor as the heart of the refrigeration system are more well known than the other three components. In addition, the evaporator is another key component. Do you know about the type and characteristics of the evapor...
view more
-
How dose sewage source heat pump works?
2019-04-16
Using domestic sewage? We are saving your MONEY! Sewage source heat pump is one of the most promising heat pump technologies in the world.It is estimated that by 2020, the new residential heating demand area in seven major provinces and cities in north China will exceed 400 million square meters.At present, the area of central heating (non-clean energy) in north China is 5.13 billion square meters...
view more
-
Pharmaceutical Factories, by Using These Ways, Can Clean the Air Conditioning System to Save 40% of the Operating Costs.
2019-05-21
Pharmaceutical factories need to meet the relevant requirements of GMP in the production process, and the temperature, humidity and cleanliness must be controlled within a certain range. Under normal circumstances, when there is no special requirement, the temperature should be controlled between 18 ° C ~ 26 ° C; the relative humidity is controlled at 45% ~ 65%. The clean area of pharmaceutical fa...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
What should you pay attention in the Design and Construction of 5000RT cold room
2019-09-12
The 5000RT cold room generally equipped with various refrigeration equipment, which can be controlled and maintained stable low temperature facilities. Its basic components are: refrigeration system, warehouse with certain thermal insulation performance, attribute buildings, etc. H.Stars Group has been committed to providing customers with complete low temperature condensing c...
view more
-
The Difference between sewage source heat pump and air source heat pump
2020-01-16
The heat pump is based on the reverse Carnot cycle principle. It doesn’t cost many electricity by refrigerant system. Using refrigerant as carrier to continuously absorb the free low-grade heat energy in the heat source and convert it into high-grade heat energy, thus realizing the transfer of low-temperature heat energy to high-temperature heat energy. According to the different heat source ,H.St...
view more
-
H.Stars Group has launched the first batch of catalogs with 9 different types
2020-03-25
H.Stars Group has launched the first batch of catalogs with 9 different types. For more details or soft copy of our catalogs, welcome to contact us sales@hstars.com.cn . After launching the first batch of 9 new catalogs, H.Stars Group has been informed by clients overseas that they start to understand our products more. The first batch of catalogs is mainly for medium and large centrifugal and scr...
view more
-
Application of double source heat pump unit in automobile painting workshop
2020-07-16
Automobile production and manufacturing process includes stamping, welding, coating and general assembly. According to relevant statistics, coating workshop involves heating, cooling, power, communication control, lighting, etc. energy consumption accounts for a large proportion in the whole manufacturing process (stamping, welding, coating, etc.), accounting for more than 70% of the cost. The gen...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more
-
90℃ dual source heat pump | Hstarschiller.com
2021-12-07
H.Stars Group has recently signed a contract with 90℃ dual source heat pump unit project for one of the famous automobile factory to replace the traditional boiler. Below are the features of high-efficiency 90-degree dual source heat pump: 1. Special design and customized size for easy installation. 2. Adopt the special compressor of Hanbell high temperature heat pump, with high compression ratio,...
view more
-
How to design heating system for a pharmaceutical factory dormitory building
2022-04-15
As we know that the simplest way to build heating system for hot water for dormitory is adopting boiler with coal burning ,which will cause CO2 increase for the earth. Here is the good example how to design the heating system with energy saving heat pumps to protect the environment. The project is the central air conditioning project and hot water project of a pharmaceutical factory dormitory buil...
view more
-
How to design the energy saving cooling system for factory production line and office building
2022-06-15
Project Overview This project is for one of the new factory buildings for one of the 500 fortune company of Dairy industry . The factory new workshop building area is about 17,000 square meters, with a total of 2 floors. H.Stars Group has helped this company to design the energy saving cooling system by adopting low-temperature chiller and low-ambient temperature air source heat pump unit Pr...
view more
-
How H.Stars help you save energy by adopting water-cooled magnetic oil free centrifugal VFD chiller
2023-01-09
As we all know , the society is urging all enterprises to fulfil their obligation on energy saving to keep the earth green for our next generations. H.Stars Group has developed a ner product of magnetic VFD oil-free centrifugal chiller to be able to provide comprehensive partial efficiency IPLV of the unit upto 10, and the partial load energy efficiency value exceeds 13. The operating noise ...
view more
-
How does a Heat Pump Work in Winter
2023-07-03
Heat pumps are essential devices used in the heating, ventilation, and air conditioning (HVAC) industry. They provide efficient heating and cooling solutions for both residential and industrial purposes. In this blog post, we will explore how a heat pump works in winter, what happens if it's too cold outside for a heat pump to work efficiently, and what you should know about using your heat pump d...
view more