Air Cooled Low Temperature Ice Skating Rink Chiller Unit

The refrigeration system of indoor ice skating rink usually adopts two refrigeration methods: direct expansion and indirect cooling. Direct expansion adopts "Hstars" brand condensing unit; indirect cooling adopts "Hstars" brand screw type low-temperature chiller, Glycol is used as a refrigerant to form ice on the rink.
Inquiry now
Product Detail


Air Cooled Low Temperature Ice Skating Rink Chiller Unit


Profile

  • The refrigeration system of indoor ice skating rink usually adopts two refrigeration methods: direct expansion and indirect cooling. Direct expansion adopts "Hstars" brand condensing unit; indirect cooling adopts "Hstars" brand screw type low-temperature chiller, Glycol is used as a refrigerant to form ice on the rink.
  • Brand: H'Stars
  • Cooling capacity range: 25KW-169KW
  • Applications: Ice Rink, Cooling tunnels, food production companies. 

Air Cooled Low Temperature Ice Skating Rink Chiller Unit


 Parameters

  • Cooling range 76kw-363kw Evaporating temperature low -45°C
  • Application area Ice rink, Chemical, cold storage

 Air Cooled Low Temperature Ice Skating Rink Chiller Unit


Type selection of refrigerating mainframe

The hardness of the ice surface determines its hardness. Generally speaking, the hardness of the ice surface at -5 degree can meet the requirements. To meet the requirements of ice temperature -5 C, the ethylene glycol solution in pipe of the ice field is set at -15 C.

At present, “Hstars” brand has both water cooled screw-type low temperature water chiller and air-cooled screw-type low temperature water chiller to be choose, also be used without the standard selection of water pump and expansion water tank. it can work immediately at site after Connect pipe and electricity, It can also increase the heat recovery device, make the hot water at the same time, which will improve the economic efficiency.


Air Cooled Low Temperature Ice Skating Rink Chiller Unit


Air conditioning professional requirements for civil design

  • In the civil construction it must have good thermal insulation measures
  • Enclosure structure should choose insulation materials with good insulation properties and low water absorption, and pay attention to the level of the gas barrier.
  • From the viewpoint of energy conservation and prevention of condensation, the windows on the walls should be made of aluminum alloy double-glazed windows.
  • Special measures to be considered in the design of air conditioning systems.



Air Cooled Low Temperature Ice Skating Rink Chiller Unit


Prevent condensation on the roof or ceiling Common technical measures 


  • The ceiling of the ceiling is made of aluminum sheet metal.
  •  Increase the surface temperature of the ceiling or roof.
  • Indoor set dehumidification device or air conditioning system


 

Eliminating ice fog

Use the following technical measures to eliminate ice fog


  • Reduce indoor wetness.
  • Send air to the ice.
  • A dehumidifier or an air-conditioning unit (independent air-conditioning unit with a chiller) is installed in the indoor rink to dehumidify the indoor air and reduce the dew point temperature of the indoor air.








Contact Us For More Details
contact experts
Contact Person: Ms May Chow Mobile/WhatsApp: +86 18665672648 Tel: +86-20-62266755 Ext. 886 Fax: +86-20-82266081 Email: maychow@hstars.com.cn
Related Products
industry chiller Air cooled screw type chiller for industry use
HStars air cooled screw type water chiller adpots Hanbell screw compressors and heat recovery optional for clients for inustry use . High quality with easy operation.
25KW ~ 142.2KW  Scroll Air cooled Industrial Chiller High cooling capacity Scroll Air cooled Industrial Chiller
20STB series scroll air-cooled industrial chiller adopts fully hermetic scroll compressor, developed high-efficiency shell and tube heat exchanger, using R22, R407c refrigerant, energy efficiency grade up to 2 levels
 Scroll Air cooled Chiller Shell and Tube Heat Exchangers Scroll Air cooled Chiller
20STB series scroll air cooled chiller adopts closed scroll compressor, independently develops and manufactures high-efficiency shell-and-tube heat exchanger and coil heat exchanger, adopts R22 and R407c refrigerants
Air-cooled Screw Chiller Industrial and Commercial Air-cooled Screw Chiller
Industrial and commercial air-cooled screw chiller is composed of  5:6 high-efficiency screw compressor  high-quality condenser and evaporator, and equipped with brand-name electrical control components,which can be used widely in different industries.
Water Cooled Low Temperature Air Conditioning Unit Water Cooled Low Temperature Air Conditioning Unit
The water-cooled low-temperature air conditioning unit adopts three-stage refrigeration and is unloaded step by step according to the cooling load demand of the use environment. The unit adopts a special microcomputer controller to control the low-temperature action process, and automatically operates after setting the temperature according to actual needs. The outer plate is made of stainless steel, which meets the hygiene requirements of food production.
Water-Cooled Cabinet Water-Cooled Cabinet
The cooling capacity of "H'Stars" water-cooled cabinets: 180KW--2380KW

Copyright © 2015-2024 H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.

/ Blog / Sitemap / XML
  • 1
  • Linkedin
  • twitter
  • instagram
  • youtube
welcome to H.Stars

Home

Products

about

contact