How to help pharmaceutical factories to save electricity on HVACR system
2019-08-30
The raw material medicine is mainly produced by raw material fermentation or chemical synthesis. No matter which production process needs to be carried out at a relatively stable low temperature. Different medicines require different temperatures, such as antibiotic raw materials need to be maintained at around 25 °C during fermentation, other chemical raw materials are produced at tempe...
view more
-
Magnetic Oil Free Centrifugal Chiller Advantages
2019-08-26
With the rapid development of the times and economy, energy conservation, environmental protection, and emission reduction have become an indispensable new era mission. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, greenhouse ef...
view more
-
The Reason That More and More People Choose Magnetic Oil Free Centrifugal Chiller
2019-07-30
With the rapid development of the times and economy, energy conservation and environmental protection and energy conservation and emission reduction have become an indispensable link. For a long time, the problems of “high energy consumption and secondary pollution” of central air-conditioning have brought great burdens to various industries. In the process of product operation, oil pollution, gre...
view more
-
The Solutions of Common Low Pressure for Chillers
2019-07-26
There are many factors that cause low-pressure failure of cold water (freezer) machines, and we only list some of them today. It can be roughly divided into the following categories (from easy to difficult sequence) system leakage, system blockage, and evaporator blockage. Important: The "Reset button" on the pressure controller must be pressed after each fault point has been processed. Common low...
view more
-
Analysis of 10 major failure phenomena commonly seen in refrigeration equipment maintenance
2019-07-05
1. The exhaust gas temperature of the refrigeration system is too low: The low exhaust pressure is mainly caused by the small or even stop flow of the refrigerant in the refrigeration system. The exhaust pressure is too low, although the phenomenon is manifested at the high pressure end, but the cause is mostly caused by the low pressure end. Common reasons for low exhaust pressure: 1) T...
view more
-
The Reason Why the Temperature of Condensers of Water Cooled Chillers are Abnormally High
2019-06-28
Why are the temperature of condensers of water cooled chiller are abnormally high? The water-cooled condenser we mention here is mainly used in water-cooled chillers. Its function is to use the high-temperature refrigerant vapor condenser discharged from the compressor as a liquid refrigerant, which is an important part of the refrigeration system to release heat to the surrounding envir...
view more
-
Summary of the Characteristics of Common Used Refrigerants
2021-03-11
The nature of the refrigerant is directly related to the refrigeration effect of the refrigerating equipment, and even personal safety. As refrigerating men, we should understand what the commonly used refrigerants are and how to operate and manage them. 1. R22 Refrigerant The aliases of R22 refrigerant are monochlorodifluoromethane, Freon 22, F-22, refrigerant HCFC-22. Freon R22 is one of the mos...
view more
-
The Solution of Cold Water of Concrete Mixing Station
2022-12-16
1.Background of the project Temperature-controlled concrete is required for large-scale pouring of large hydro power dams, nuclear power, high-speed iron, and high-rise building foundations. During the concrete mixing process, the internal volume of the concrete hydration heat increases, especially the heat generated by the stirring under high temperature conditions is higher. In the subsequent cu...
view more
-
The three major drawbacks of the refrigeration equipment industry urgently need to be solved
2019-05-30
Refrigeration equipment is now widely used in various fields, and different industry requirements for equipment specifications are also different. With the expansion of various industries, the requirements and goals for refrigeration equipment are higher and higher. From the current situation, China's refrigeration industry still has many shortcomings, and its most obvious performance is the follo...
view more