-
H.Stars High precision chiller can control temperature within 0.1℃
2019-09-09
1. Some special production processes such as: testing, precision material testing, precision instrument cooling water system, etc., need to ensure that the circulating cooling water inlet water constant temperature or high precision, so that the data or product performance is stable. 2. Water for food and medicine must ensure the temperature of the mixing water to ensure the stability of...
view more
-
What should you pay attention in the Design and Construction of 5000RT cold room
2019-09-12
The 5000RT cold room generally equipped with various refrigeration equipment, which can be controlled and maintained stable low temperature facilities. Its basic components are: refrigeration system, warehouse with certain thermal insulation performance, attribute buildings, etc. H.Stars Group has been committed to providing customers with complete low temperature condensing c...
view more
-
How to find the right Explosion-proof chillers for industrial process cooling
2019-11-15
Introduction of explosion-proof chiller: International Industries have demanded a lot from their HVAC machines. Some of equipment might be susceptible to explosions inside and outside their circuitry. Getting an explosion-proof chiller is essential for many industrial environments. However ,very few factory can manufacture explosion-proof chillers with mature technology and ski...
view more
-
How to produce a coil heat exchanger
2020-04-17
As we all know, coil heat exchangers are very important part of a air cooled chiller and air source heat pumps. How does a factory produce coil heat exchangers? Below are total 9 different procedures to maintain superior quality products. 1. Material preparation (copper tube, end plate, side plate, middle support plate, short U-head, gas / liquid tube, liquid distribution tube) 2. Fin stamping (pu...
view more
-
Magnetic Bearing Centrifugal Chiller Units
2020-04-30
Magnetic Bearing Centrifugal Chiller installed for one of the commercial building This is a central air-conditioning project for the Industrial bank commercial building. The office has a total air-conditioning area of 8,000 square meters and other supporting areas of 2000 square meters. Device configuration instructions of Magnetic Bearing Centrifugal Chiller Units This project has selected two un...
view more
-
Shell and tube heat exchanger gaskets options
2020-06-06
In the design and manufacturing process of UAR shell and tube heat exchangers, how to ensure the encapsulation of the product is a very important topic. At present, there are many seal materials available on the market, the media in the container are diversified, and the physical properties of various media vary greatly. Choosing the right sealing gasket according to the working conditions a...
view more
-
Application of double source heat pump unit in automobile painting workshop
2020-07-16
Automobile production and manufacturing process includes stamping, welding, coating and general assembly. According to relevant statistics, coating workshop involves heating, cooling, power, communication control, lighting, etc. energy consumption accounts for a large proportion in the whole manufacturing process (stamping, welding, coating, etc.), accounting for more than 70% of the cost. The gen...
view more
-
Impact of New Coronavirus (COVID-19) on Refrigeration
2020-07-23
The current epidemic situation has changed both China and the world. Many companies are facing severe crises, and some large companies cannot bear it. They have begun to reduce personnel costs. News broke out one after another, Hisense Haier layoffs, and some companies laid off 500 people on the first day of resumption of work. In the next six months or longer, regardless of whether large, medium ...
view more
-
H.Stars ±0.1℃ high-precision chiller for Laboratory of the university
2020-09-03
Project Background The Synchrotron Radiation Laboratory of the University of Science and Technology of China has built China's first dedicated synchrotron radiation source mainly based on vacuum ultraviolet and soft X-rays. To ensure the reliability and stability of the light source, it is necessary to provide stable constant-temperature cooling water in the device. The temperature should be contr...
view more
-
Meet in Chongqing,Meet in Refrigeration Exhibition | Hstarschiller.com
2020-09-03
The 31st International Exhibition on Refrigeration, Air Conditioning, Heating, Ventilation and Food Frozen Exhibition (abbreviated as China Refrigeration Expo 2020) will be held at Chongqing International Expo Center from August 19 to 21, 2020. At that time, Guangzhou United A/C&R Co., Ltd. will bring its self-developed all-stainless steel products, titanium tube evaporator, and H.Stars ...
view more
-
H.Stars Group industrial water screw chillers are ranked top 75 of the world tire industry
2020-09-03
Anhui Jiatong Tire Co., Ltd. is a large-scale tire manufacturing enterprise solely established by Jiatong Group Singapore Jiatong Tire Co., Ltd. Among the 55 major tire manufacturers in China, Anhui Jiatong ranks first in tire production and sales; in the world tire industry The Top 75 ranked 21st in total sales in 2001. The chilled water supply system mainly provides 7-12℃ chilled...
view more
-
Basic requirements for structural design of low temperature heat exchanger
2020-09-09
Carbon steel and low-alloy steel heat exchangers (design temperature lower than -20℃), austenitic stainless steel heat exchangers (design temperature lower than -196℃) are low temperature heat exchangers, and the structural design should follow the following in principle. Material selection of low temperature heat exchanger: 1. Use temperature of plastic materials Polyvinyl chloride (PVC) -15℃~+80...
view more
-
How Does H.Stars Group Produce A High Quality Water Cooled Chiller
2020-09-18
Since H.Stars Group has been established for more than 28 years so far, some of you might wonder how H.Stars produces a high quality water cooled chiller. Below is the detailed production process with strict quality control system and 100% testing before delivery. 1. Chiller Frame welding: clean the bracket and select the appropriate welding method according to the specifications of the welding ma...
view more
-
Comparison Between Magnetic Centrifugal Chiller with Screw Chiller Difference Point and Advantage
2024-04-11
It is understood that the magnetic bearing chiller is a new type of centrifuge equipment appearing in the international market. Compare to screw chillerIts main characteristics are fast speed, low noise, energy saving, intelligent management, in line with the trend of green development, and the magnetic levitation technology is in the world's leading level. Magnetic levitation compressor . bearing...
view more
-
How to do daily maintenance for air-cooled chillers | Hstarschiller.com
2020-11-10
Air-cooled chillers, as a kind of more efficient refrigeration equipment in chiller products, are widely used in the domestic industrial market and become necessary equipment for many industrial production. At the same time, although the air-cooled chiller is equipped with multiple protection devices, these are all to prevent the failure from directly damaging the unit. If the company wants to ens...
view more
-
The Role and Characteristics of Condenser in Refrigeration System
2020-11-16
The four major components of the refrigeration system are compressor, evaporator, condenser and throttling device. The role of the condenser in the refrigeration system is mainly to cool and liquefy the gaseous refrigerant in the high temperature and high pressure state discharged from the compressor, so as to meet the requirements of the circulating use of the refrigerant in the system. The selec...
view more
-
What is a plate and shell heat exchanger | Hstarschiller.com
2020-12-07
The plate and shell heat exchanger is composed of a plate bundle composed of a plate group and a shell. It is a plasma arc welded corrugated plate group placed in the shell instead of the heat exchange tube of the original shell and tube heat exchanger. The plate group is used as the heat exchanger of the heat transfer element. The two fluid media respectively flow through the plate side and the s...
view more
-
Tips for seasonal water chiller system shutdown in winter
2021-03-12
Introduction: Winter is coming, and the ambient temperature is about to drop below zero. This will cause great damage to the chillers, water pumps, cooling towers, terminals and other equipment. In order to ensure that chillers work normally during winter, the chiller has to survive in the low temperature environment, because it will cause a great loss to users if the unit is not maintained with p...
view more